100M 1 Optical Port 4 Electrical Port  Industrial Ethernet Switch (GL-7014F Series)
100M 1 Optical Port 4 Electrical Port  Industrial Ethernet Switch (GL-7014F Series)
100M 1 Optical Port 4 Electrical Port  Industrial Ethernet Switch (GL-7014F Series)
100M 1 Optical Port 4 Electrical Port  Industrial Ethernet Switch (GL-7014F Series)
100M 1 Optical Port 4 Electrical Port  Industrial Ethernet Switch (GL-7014F Series)
  • 100M 1 Optical Port 4 Electrical Port  Industrial Ethernet Switch (GL-7014F Series)
  • 100M 1 Optical Port 4 Electrical Port  Industrial Ethernet Switch (GL-7014F Series)
  • 100M 1 Optical Port 4 Electrical Port  Industrial Ethernet Switch (GL-7014F Series)
  • 100M 1 Optical Port 4 Electrical Port  Industrial Ethernet Switch (GL-7014F Series)
  • 100M 1 Optical Port 4 Electrical Port  Industrial Ethernet Switch (GL-7014F Series)

100M 1 Optical Port 4 Electrical Port Industrial Ethernet Switch (GL-7014F Series)

Use high-quality photoelectric integrated modules to provide good optical and electrical characteristics Ensure reliable data transmission and long working life Support full-duplex or half-duplex mode with auto-negotiation capability The network port supports automatic cross-recognition Built-in store and forward mechanism, support multiple protocols In line with industrial-grade operation standards, the average trouble-free work is more than 300,000 hours Working power supply: DC 12-52V provides reverse connection protection Use SC/FC/ST/SFP fiber interface Lightning surge protection (power supply): 5000A (8/20μs))

Category:

Industrial Ethernet Switches

Product Details

Product Features

Use high-quality photoelectric integrated modules to provide good optical and electrical characteristics

Ensure reliable data transmission and long working life

Support full-duplex or half-duplex mode with auto-negotiation capability

The network port supports automatic cross-recognition

Built-in store and forward mechanism, support multiple protocols

In line with industrial-grade operation standards, the average trouble-free work is more than 300,000 hours

Working power supply: DC 12-52V provides reverse connection protection

Use SC/FC/ST/SFP fiber interface

Lightning surge protection (power supply): 5000A (8/20μs))

 

Product Description

4 100M electrical ports + 1 100M FX optical port industrial Ethernet switch, supporting 4 10Base-T/100Base-TX electrical ports and 1 100Base-X optical port. Products comply with FCC, CE, ROHS standards. The GL-7014F series switches have an operating temperature of -30°C to 75°C. They are extremely robust and can adapt to various harsh environments. They can also be conveniently placed in a compact control box. The installation characteristics of the guide rail, wide temperature operation, and IP40 protection class enclosure and LED indicator light make GL-7014F a plug-and-play industrial-grade device, providing a reliable and convenient solution for users' Ethernet device networking.

 

Technical Index

Product name: 100M 1 optical 4 electrical industrial-grade Ethernet switch

Product model: ZX14F series

Product description: 4 100M electrical ports + 1 100M optical port industrial Ethernet switch

Port description: 4 RJ45 ports + 1 optical fiber interface

Optical fiber port: 100BaseFX port (SC/FC/ST/SFP optional)

RJ45 port: 10/100BaseT (X) automatic detection, full/half duplex MDI/MDI-X adaptive

Network protocol: IEEE802.310BASE-T IEEE802.3i, 10Base-T; IEEE802.3u; 100Base-TX/FX;, IEEE802.3ab1000Base-T; IEEE802.3z1000Base-X; IEEE802.3x;, IEEE802.3af, IEEE802.3at

Working temperature: -30~75 °C (-30~175 °F)

Storage temperature: -40~75 °C (-40~175 °F)

Relative humidity: 5%~95% (non-condensing)

Power supply: support built-in overcurrent 4.0A protection, support reverse connection protection

Input voltage: DC12-52V

Access terminal: Phoenix terminal

Shell: IP40 protection grade, metal shell

Installation: DIN rail type, wall-mounted installation

Cooling method: natural cooling, no fan

Weight: 0.36Kg

Dimensions: 105x74 x 30mm (width x depth x height)

Power indicator: PWR

Interface indicator: electrical port, optical port (Link/ACT)

Protection level: IP40

Certification: CE, FCC, Rohs, ISO9001: 2008 Ministry of Industry and Information Technology Network Access License Ministry of Public Security Inspection Report

Safety: UL508

Mean time between failures: 300,000 hours

Warranty: 3 years

Application level: Layer 2

Total backplane bandwidth: 1.52Gbps

Package forwarding rate of the whole machine: 1.13088Mpps

MAC table: 1K

Packet buffer: 512K

Delay time: <3μs

Exchange method: store-forward

Whole machine power consumption: <3W

Industry Standard:

EMI: FCC Part 15 Subpart B Class A, EN 55022 Class A

EMS:

IEC(EN)61000-4-2(ESD): ±8kV contact discharge, ±12kV air discharge

IEC(EN)61000-4-3(RS): 10V/m(80~1000MHz)

IEC(EN)61000-4-4(EFT): Ethernet port: ±4kV CM//±2kV DM;

IEC(EN)61000-4-5(Surge): Ethernet port: ±4kV CM//±2kV DM;

IEC(EN)61000-4-6 (Radio Frequency Conduction): 3V(10kHz~150kHz), 10V(150kHz~80MHz)

IEC(EN)61000-4-16 (common mode conduction): 30V cont. 300V, 1s

IEC(EN)61000-4-8

Shock: IEC 60068-2-27

Freefall: IEC 60068-2-32

Vibration: IEC 60068-2-6

 

Order Information

Model

Description

GL-7014F-SC2

1 100M optical + 4 100M power, SC interface, multimode dual fiber, 2km, rail type, DC12-48V power supply-wide temperature (-30℃-75℃)

GL-7014F-SC20

1 100M optical + 4 100M power, SC interface, single-mode dual-fiber, 20 km, rail type, DC12-48V power supply-wide temperature (-30℃-75℃)

GL-7014F-SC20A/B

1 100M optical + 4 100M power, SC interface, single mode single fiber, 20 kilometers, rail type, DC12-48V power supply-wide temperature (-30℃-75℃)

GL-7014F-FC2

1 100M optical + 4 100M power, FC interface, multi-mode dual fiber, 2 km, rail type, DC12-48V power supply-wide temperature (-30℃-75℃)

GL-7014F-FC20

1 100M optical + 4 100M power, FC interface, single-mode dual-fiber, 20 km, rail type, DC12-48V power supply-wide temperature (-30℃-75℃)

GL-7014F-FC20A/B

1 100M optical + 4 100M power, FC interface, single mode single fiber, 20 km, rail type, DC12-48V power supply-wide temperature (-30℃-75℃)

GL-7014F-ST2

1 100M optical + 4 100M power, ST interface, multi-mode dual fiber, 2 km, rail type, DC12-48V power supply-wide temperature (-30℃-75℃)

GL-7014F-ST20

1 100M optical + 4 100M power, ST interface, single-mode dual-fiber, 20 km, rail type, DC12-48V power supply-wide temperature (-30℃-75℃)

GL-7014F-ST20A/B

1 100M optical + 4 100M power, ST interface, single mode single fiber, 20 km, rail type, DC12-48V power supply-wide temperature (-30℃-75℃)

Adapter

ZX5121-DC

12V/1A, suitable for non-POE industrial switch product series.

ZX5241-DC

24V/1A, suitable for non-POE industrial switch product series.

Appearance

 

Application

Exhibition Preview

Production Environment
Production Environment
Production Environment
Production Environment
Production Environment
Production Environment
Production Environment
Production Environment

FAQ

Listed below are answers to our most commonly asked questions. Don't see your question?Contact our customer service team. We would be glad to assist you.

What is an optical network terminal (ONT)? How does it differ from a regular modem?

An optical network unit (ONU) is an end device in a fiber optic network that converts optical signals transmitted via fiber optics into electrical signals (for use by routers, computers, and other devices), and vice versa.

What is the architecture of a fiber optic network (PON)?

Fiber optic networks typically use a passive optical network (PON) architecture, which is divided into three layers

What are the functions of the PON port and LAN port on an optical network terminal (ONT)?

PON port (fiber optic interface): Connects to the fiber optic cable entering the home and receives optical signals (usually SC/APC interface, blue square head).

Why does the optical network terminal need to register LOID/SN?

LOID (Logical Identifier) or SN (Serial Number) is the credential used by operators to bind user identities, and is used for OLT authentication of optical modems.

Optical modem dialing vs. router dialing: which is better?

Ordinary users: Optical modem dialing. Game/NAS users: Switch to bridge mode and dial up using a high-performance router.

How to determine whether the fiber optic signal is normal?

Check the optical modem indicator lights Log in to the optical modem management interface: Check the optical power (unit: dBm)

Send enquiry

NOTE: Please leave your email, our professionals will contact you ASAP!