10G/s BIDI SFP+ Transceiver, 40km Reach GL-W40S-LC27/33-SFP
10G/s BIDI SFP+ Transceiver, 40km Reach GL-W40S-LC27/33-SFP
10G/s BIDI SFP+ Transceiver, 40km Reach GL-W40S-LC27/33-SFP
10G/s BIDI SFP+ Transceiver, 40km Reach GL-W40S-LC27/33-SFP
10G/s BIDI SFP+ Transceiver, 40km Reach GL-W40S-LC27/33-SFP
10G/s BIDI SFP+ Transceiver, 40km Reach GL-W40S-LC27/33-SFP
10G/s BIDI SFP+ Transceiver, 40km Reach GL-W40S-LC27/33-SFP
  • 10G/s BIDI SFP+ Transceiver, 40km Reach GL-W40S-LC27/33-SFP
  • 10G/s BIDI SFP+ Transceiver, 40km Reach GL-W40S-LC27/33-SFP
  • 10G/s BIDI SFP+ Transceiver, 40km Reach GL-W40S-LC27/33-SFP
  • 10G/s BIDI SFP+ Transceiver, 40km Reach GL-W40S-LC27/33-SFP
  • 10G/s BIDI SFP+ Transceiver, 40km Reach GL-W40S-LC27/33-SFP
  • 10G/s BIDI SFP+ Transceiver, 40km Reach GL-W40S-LC27/33-SFP
  • 10G/s BIDI SFP+ Transceiver, 40km Reach GL-W40S-LC27/33-SFP

10G/s BIDI SFP+ Transceiver, 40km Reach GL-W40S-LC27/33-SFP

10Gbps Ethernet or SONET/SDH switches and routers 10G/8.5G/4.25G/2.125G/1.0625G Fiber Channel Other 10Gbps optical links

Category:

SFP optical module

Product Details

Features

Fiber Bi-Directional SFP+ Optical Transceiver

Electrical interface compliant to SFF-8431

Hot Pluggable

Up to 10.7Gbps Data Links

1270/1330nm DFB LD Transmitter

1270/1330nm PIN Receiver

Low power consumption 

Applicable for 40km SMF connection

All-metal housing for superior EMI performance

Advanced firmware allow customer system encryption information to be stored in transceiver

Cost effective SFP+ solution, enables higher port densities and greater bandwidth

Operating case temperature: 0 to 70 °C

 

Applications

10Gbps Ethernet or SONET/SDH switches and routers

10G/8.5G/4.25G/2.125G/1.0625G Fiber Channel

Other 10Gbps optical links

 

Product description

This 1270//1330nm DFB 10Gigabit SFP+ transceiver is designed to transmit and receive optical data over single mode optical fiber for link length 40km.  

The BI-DI SFP+ LR module electrical interface is compliant to SFI electrical specifications.  The transmitter input and receiver output impedance is 100 Ohms differential.  Data lines are internally AC coupled.  The module provides differential termination and reduce differential to common mode conversion for quality signal termination and low EMI. SFI typically operates over 200 mm of improved FR4 material or up to about 150mmof standard FR4 with one connector.

In the transmit direction, the SFP+ transceiver module receives a 10.3125Gb/s electrical signal(signaling rate) from the host board ASIC/SERDES and converts the data to an optical signal via the Laser Driver that controls the Laser diode in the Transmitter Optical Sub-Assembly (TOSA).  An open collector compatible Transmit Disable (Tx_Dis) is provided.  A logic “1,” or no connection on this pin will disable the laser from transmitting.  A logic “0” on this pin provides normal operation.  The transmitter has an internal automatic power control loop (APC) to ensure constant optical power output across supply voltage and temperature variations.  An open collector compatible Transmit Fault (T Fault) is provided.  TX_Fault is a module output contact that when high, indicates that the module transmitter has detected a fault condition related to laser operation or safety.  The TX_Fault output contact is an open drain/collector and shall be pulled up to the Vcc_Host in the host with a resistor in the range 4.7-10 kΩ.   TX_Disable is a module input contact. When TX_Disable is asserted high or left open, the SFP+ module transmitter output shall be turned off. This contact shall be pulled up to VccT with a 4.7 kΩ to 10 kΩ resistor

The receiver converts 10Gbit/s serial optical data into serial PECL/CML electrical data.  An open collector compatible Loss of Signal is provided.  Rx_LOS when high indicates an optical signal level below that specified in the relevant standard.  The Rx_LOS contact is an open drain/collector output and shall be pulled up to Vcc_Host in the host with a resistor in the range 4.7-10 kΩ, or with an active termination.  Power supply filtering is recommended for both the transmitter and receiver.   The Rx_LOS signal is intended as a preliminary indication to the system in which the SFP+ is installed that the received signal strength is below the specified range. Such an indication typically points to non-installed cables, broken cables, or a disabled, failing or a powered off transmitter at the far end of the cable.

The 3rd functional capability of the SFP+ module is the 2 wire serial, I2C, interface.  I2C is used for serial ID, digital diagnostics, and module control functions. The enhanced digital diagnostics monitoring interface allows real time access to the device allowing monitor of received optical power, laser bias current, laser optical output power, etc.

Figure 1: Interface to Host

 

Pin definition 

The SFP+ modules are hot-pluggable.  Hot pluggable refers to plugging in or unplugging a module while the host board is powered.  The SFP+ host connector is a 0.8 mm pitch 20 position right angle improved connector specified by SFF-8083, or stacked connector with equivalent with equivalent electrical performance.   Host PCB contact assignment is shown in Figure 2 and contact definitions are given in Table 2.   SFP+ module contacts mates with the host in the order of ground, power, followed by signal as illustrated by Figure 3 and the contact sequence order listed in Table 2.

Figure 2: Interface to Host PCB

Figure 3: Module Contact Assignment

Table 2: SFP+ Module PIN Definition

 

Absolute maximum rating 

These values represent the damage threshold of the module.  Stress in excess of any of the individual Absolute Maximum Ratings can cause immediate catastrophic damage to the module even if all other parameters are within Recommended Operating Conditions.

Parameters

Symbol

Min.

Max.

Unit

Power Supply Voltage

VCC

0

+3.6

V

Storage Temperature

Tc

-40

+85

°C

Operating Case Temperature

Tc

0

+70

°C

Relative Humidity

RH

5

95

%

RX Input Average Power

Pmax

-

0

dBm

Table 3: Absolute Maximum Rating

 

Recommended operating environment 

Recommended Operating Environment specifies parameters for which the electrical and optical characteristics hold unless otherwise noted. 

Parameter

Symbol

Min.

Typical

Max

Unit

Power Supply Voltage

VCC

3.135

3.300

3.465

V

Operating Case Temperature

TC

0

25

70

°C

Table 4: Recommended Operating Environment

 

Optical characteristics

The following optical characteristics are defined over the Recommended Operating Environment unless otherwise specified.

 

Unit

Values

Operating Reach

m

10K

Transmit 

Center wavelength (range)

nm

1260 -1355

Side Mode Suppression Ratio (min)

dB

30

   Launched power

– maximum 

dBm

+0.5

– minimum

dBm

              -8.2      Notes1

  • OMA

dBm

-5.2

  • OMA-TDP (min)

dBm

-6.2

Transmitter and dispersion penalty

dB

               0        Notes4

Average launch power of OFF transmitter (max)

dBm

-30

  Extinction ratio (min)

dB

             3.5     Notes2

RIN12 OMA (max)

dB/Hz

-128

Optical Return Loss Tolerance (min)

dB

12

Receiver 

Center wavelength (range)

nm

1260-1355

Receive overload (max) in average power1

dBm

0.5

Receive sensitivity (min) in average power1

dBm

 -14.4    Notes3 (40km)

dBm

 -13.4    Notes3 (20km)

Receiver sensitivity (max) in OMA (footnote 2)

dBm

  -12.6    Notes3 (10km)

dBm

 -11.6    Notes3 (20km)

Receiver Reflectance (max)

dB

-12

Stressed receiver sensitivity (max) in OMA2 

dBm

-10.3

Vertical eye closure penalty (min)3

dB

2.2

Stressed eye jitter (min)2

UIp-p

0.7

Receive electrical 3dB upper cutoff frequency (max)

GHz

12.3

Receiver power (damage, Max)

dBm

1.5

Notes:

The optical power is launched into SMF

Measured with a PRBS 231-1 test pattern@10.3125Gbps

Measured with a PRBS 231-1 test pattern@10.3125Gbps BER≤10-12

 In G.652 and G.655(NDSF)

Table 5: Optical Characteristics

 

Electrical characteristics

The following electrical characteristics are defined over the Recommended Operating Environment unless otherwise specified.

Parameter

Symbol

Min.

Typical

Max

Unit

Notes

Data Rate

 

-

10.3125

-

Gbps

 

Power Consumption

 

-

1200

1500

mW

 

Transmitter

Single Ended Output Voltage Tolerance

 

-0.3

-

4.0

V

 

C common mode voltage tolerance

 

15

-

-

mV

 

Tx Input Diff Voltage

VI

400

 

1600

mV

 

Tx Fault

VoL

-0.3

 

0.4

V

At 0.7mA

Data Dependent Input Jitter

DDJ

 

 

0.10

UI

 

Data Input Total Jitter

TJ

 

 

0.28

UI

 

Receiver

Single Ended Output Voltage Tolerance

 

-0.3

-

4.0

V

 

Rx Output Diff Voltage

Vo

300

 

850

mV

 

Rx Output Rise and Fall Time

Tr/Tf

30

 

 

ps

20% to 80%

Total Jitter

TJ

 

 

0.70

UI

 

Deterministic Jitter

DJ

 

 

0.42

UI

 

Table 6: Electrical Characteristics

 

Conrtol and status I/O timing characteristics

Timing characteristics of control and status I/O are included in Table 7, which is also defined in SFF-

8431.

Exhibition Preview

Production Environment
Production Environment
Production Environment
Production Environment
Production Environment
Production Environment
Production Environment
Production Environment

FAQ

Listed below are answers to our most commonly asked questions. Don't see your question?Contact our customer service team. We would be glad to assist you.

What is an optical network terminal (ONT)? How does it differ from a regular modem?

An optical network unit (ONU) is an end device in a fiber optic network that converts optical signals transmitted via fiber optics into electrical signals (for use by routers, computers, and other devices), and vice versa.

What is the architecture of a fiber optic network (PON)?

Fiber optic networks typically use a passive optical network (PON) architecture, which is divided into three layers

What are the functions of the PON port and LAN port on an optical network terminal (ONT)?

PON port (fiber optic interface): Connects to the fiber optic cable entering the home and receives optical signals (usually SC/APC interface, blue square head).

Why does the optical network terminal need to register LOID/SN?

LOID (Logical Identifier) or SN (Serial Number) is the credential used by operators to bind user identities, and is used for OLT authentication of optical modems.

Optical modem dialing vs. router dialing: which is better?

Ordinary users: Optical modem dialing. Game/NAS users: Switch to bridge mode and dial up using a high-performance router.

How to determine whether the fiber optic signal is normal?

Check the optical modem indicator lights Log in to the optical modem management interface: Check the optical power (unit: dBm)

Send enquiry