Features
Supports 10Gb/s serial optical interface
Up to 300m transmission on OM3 MMF
850nm VCSEL laser and PIN receiver
Hot-pluggable SFP+ footprint
SFI high speed electrical interface
Built-in digital diagnostic functions
Single +3.3V power supply
Power consumption less than 0.75 W
Operating case temperature: 0~+70°C
SFP+ MSA package with duplex LC connector
Applications
10GBASE-SR/SW 10G Ethernet
Other optical links
Standard
Compliant with SFF-8472 and SFP+ MSA
Compliant to SFF-8431 and SFF-8432
Compliant with IEEE 802.3ae 10GBASE-SR/SW
Compliant with FCC 47 CFR Part 15, Class B
Compliant with Telcordia GR-468-CORE
RoHS Compliant
Table 1. Regulatory Compliance
Feature | Standard | Performance |
Electrostatic Discharge(ESD) to the Electrical Pins | MIL-STD-883E Method 3015.7 | Class 1(>1000V for SFI pins, >2000V for other pins.) |
Electrostatic Discharge (ESD) to the Duplex LC Receptacle | IEC 61000-4-2 GR-1089-CORE | Compatible with standards |
Electromagnetic nterference (EMI) | FCC Part 15 Class B EN55022 Class B (CISPR 22B) VCCI Class B | Compatible with standards |
Immunity | IEC 61000-4-3 | Compatible with standards |
Laser Eye Safety | FDA 21CFR 1040.10 and 1040.11 | Compatible with Class I laser product |
RoHS | 2002/95/EC 4.1&4.2 2011/65/EU | Compatible with standards |
Product Description
The SFP+ transceivers are high performance, cost effective modules supporting data rate of 10Gbps and 300m transmission distance with OM3 MMF. The transceiver consists of three sections: a Un-cooled 850nm VCSEL laser transmitter, a PIN photodiode integrated with a trans-impedance preamplifier (TIA) and MCU control unit. All modules satisfy class I laser safety requirements.
The transceivers are compatible with SFP Multi-Source Agreement and SFF-8472 digital diagnostics functions.

Figure 1.Transceiver functional Block Diagram
Absolute Maximum Ratings
Table 2. Absolute Maximum Ratings
(Exceeding the limits below may damage the transceiver module permanently)
Parameter | Symbol | Min | Typ | Max | Unit | Notes |
Maximum Supply Voltage | VCC | -0.5 | - | +4.0 | V |
|
Storage Temperature | TS | -40 | - | +85 | °C |
|
Case Operating Temperature | TA | -5 | - | +75 | °C |
|
Relative Humidity | RH | 5 | - | 85 | % | 1 |
Notes:
1. Non-condensing.
Recommend Operation Environment
Table 3. Recommend Operation Environment
Parameter | Symbol | Min | Typ | Max | Unit | Notes |
Data Rate | BR | - | 10.3125 | - | Gbps |
|
Power Supply Voltage | VCC | 3.13 | 3.3 | 3.47 | V |
|
Power Supply Current | ICC | - | - | 220 | mA |
|
Power Dissipation | PD | - | - | 0.75 | W |
|
Case Operating Temperature | TA | 0 | - | +70 | °C |
|
Transmission Distance | TD | - | - | 300 | m | 1 |
Notes:
1. Measured with ITU-T G.651 OM3 MMF
Electricalptical Characteristics
Table 4. Electrical Characteristics(TOP = 0 to +70 °C, VCC = 3.13 to 3.47 V)
Parameter | Symbol | Min | Typ | Max | Unit | Notes |
Transmitter | ||||||
Differential Data Input Amplitude | VIN,P-P | 180 | - | 700 | mVpp | 1 |
Input Differential Impedance | ZIN | 90 | 100 | 110 | Ω |
|
Transmitter Fault Output-High | VOH | 2.4 | - | VCC | V |
|
Transmitter Fault Output-Low | VOL | -0.3 | - | 0.4 | V |
|
Transmitter Disable Voltage- High | VIH | 2.0 | - | VCC | V |
|
Transmitter Disable Voltage- low | VIL | 0 | - | 0.8 | V |
|
Receiver | ||||||
Differential output voltage swing | VOUT,P-P | 300 | - | 850 | mVpp | 1 |
Output Differential Impedance | ZOUT | 90 | 100 | 110 | Ω |
|
Deterministic Jitter | DJ | - | - | 0.42 | UI |
|
Total Jitte | TJ | - | - | 0.70 | UI |
|
LOS Output Voltage-High | VLOSH | 2.0 | - | VCC | V | 3 |
LOS Output Voltage-Low | VLOSL | - | - | 0.8 | V | 3 |
Notes:
- CML input/output, internally AC-coupled and terminated.
Optical Characteristics
Table 5. Optical Characteristics(TOP = 0 to +70 °C, VCC = 3.13 to 3.47 V)
Parameter | Symbol | Min | Typ | Max | Unit | Notes |
Transmitter | ||||||
Optical Center Wavelength | λC | 840 | 850 | 860 | nm |
|
Data Rate | BR | - | 10.3125 | - | Gbps |
|
Average Output Power | PO | -6.5 | - | -0.5 | dBm |
|
Optical Extinction Ratio | ER | 3.0 | - | - | dB |
|
RMS Spectral Width | σ | - | - | 0.6 | nm |
|
Data Dependent Jitter | DDJ | - | - | 0.10 | UI |
|
Total Jitte | TJ | - | - | 0.28 | UI |
|
Transmitter and Dispersion Penalty | TDP | - | - | 3.9 | dB |
|
Average Launch power of Tx OFF | POFF | - | - | -30 | dBm |
|
Optical Eye Mask | Compliant with IEEE 802.3ae-2005 and ITU-T G.691 | |||||
Receiver | ||||||
Center Wavelength Range | λC | 840 | 850 | 860 | nm |
|
Data Rate | BR | - | 10.3125 | - | Gbps |
|
Receiver Sensitivity | RSEN | - | - | -11.1 | dBm | 1 |
Stressed Receiver Sensitivity (OMA) | RSENS | - | - | -7.5 | dBm |
|
Maximum Input Power | PMAX | 0 | - | - | dB | 1 |
LOS Assert | LOSA | -28 | - | - | dBm |
|
LOS De-Assert | LOSD | - | - | -13 | dBm |
|
LOS Hysteresis | LOSH | 0.5 | - | 5 | dB |
|
Receiver Reflectance | RR | - | - | -12 | dB |
|
Notes:
1. Measured with worst ER=3.0dB, RPBS 2^31-1 test pattern @10.3125Gbps BER=<10^-12.
Table 6. Timing and Electrical
Parameter | Symbol | Min | Typ | Max | Unit |
Tx Disable Negate Time | t_on | - | - | 1 | ms |
Tx Disable Assert Time | t_off | - | - | 10 | μs |
Time To Initialize,including Reset of Tx Fault | t_init | - | - | 300 | ms |
Tx Fault Assert Time | t_fault | - | - | 100 | μs |
Tx Fault To Reset | t_reset | 10 | - | - | μs |
LOS Assert Time | t_loss_on | - | - | 100 | μs |
LOS De-assert Time | t_loss_off | - | - | 100 | μs |
Serial ID Clock Rate | f_serial_clock | - | - | 400 | KHz |
SDA,SCL,MOD_ABS High Level | VH | 2 | - | Vcc | V |
SDA,SCL,MOD_ABS Low Level | VL | - | - | 0.8 | V |
Pin Assignment
Table 7. Pin Descriptions
Pin | Symbol | Name/Description | Notes |
1 | VEET | Module Transmitter Ground |
|
2 | Tx_Fault | Module Transmitter Fault | 1 |
3 | Tx_Disable | Transmitter Disable,Turns off transmitter laser output | 2 |
4 | SDA | 2 wire serial interface data input/output(SDA) | 1 |
5 | SCL | 2 wire serial interface clock input(SCL) | 1 |
6 | MOD_ABS | Module Absent,connected to VeeT or VeeR in the module | 1 |
7 | RSO | Receiver Rate Select |
|
8 | Rx_LOS | Loss of Signal indication,Logic 0 indicates normal operation | 3 |
9 | RS1 | Transmitter Rate Select,Not Used for this product |
|
10 | VEER | Module Receiver Ground |
|
11 | VEER | Module Receiver Ground |
|
12 | RD- | Receiver Inverted Data Output,AC Coupled | 4 |
13 | RD+ | Receiver Non-Inverted Data Output,AC Coupled | 4 |
14 | VEER | Module Receiver Ground |
|
15 | VccR | Module Receiver 3.3 V Supply |
|
16 | VccT | Module Transmitter 3.3 VSupply |
|
17 | VEET | Module Transmitter Ground |
|
18 | TD+ | Transmitter Non-Inverted Data Input,AC Coupled | 5 |
19 | TD- | Transmitter Inverted Data Input,AC Coupled | 5 |
20 | VEET | Module Transmitter Ground |
Notes:
1. Open collector/drain output, which should be pulled up with a 4.7kΩ to 10kΩ resistor on the host board if intended for use. Pull up voltage should be between 2.0V to 3.6V. A high output indicates a transmitter fault caused by either the TX bias current or the TX output power exceeding the preset alarm thresholds. A low output indicates normal operation. In the low state, the output is pulled to <0.8V.
2. Laser output disabled on Tx_Disable >2.0V or open, enabled on Tx_Disable <0.8V.
3. LOS is open collector output. Should be pulled up with 4.7kΩ to 10kΩ on host board to a voltage between 2.0V and 3.6V. Logic 0 indicates normal operation; logic 1 indicates loss of signal.
4. RD-/+: These are the differential receiver outputs. They are internally AC-coupled 100Ω differential lines which should be terminated with 100Ω (differential) at the user SERDES.
5. TD-/+: These are the differential transmitter inputs. They are internally AC-coupled, differential lines with 100Ω differential termination inside the module.
Pin Assignment (continued)

Figure 2. Host PCB SFP+ pad assignment top view and Names.
Digital Diagnostic Memory Map
The transceivers provide serial ID memory contents and diagnostic information about the present operating conditions by the 2-wire serial interface (SCL, SDA).
The diagnostic information with internal calibration or external calibration all are implemented, including received power monitoring, transmitted power monitoring, bias current monitoring, supply voltage monitoring and temperature monitoring.
The digital diagnostic memory map specific data field defines as following.
Table 8. Digital Diagnostic Memory Map (Specific Data Field Descriptions)

Table 9. Digital Diagnostic Monitor Characteristics
Parameter | Calibration | Range | Accuracy | Unit |
Transceiver Internal Temperature | Internal | 0 to +70°C | ±3.0 | °C |
VCC3 Internal Supply Voltage | Internal | 3.0 to 3.6V | ±3.0 | % |
Laser Bias Current | Internal | 0 to 20mA | ±10 | % |
Tx Output Power | Internal | -7.5 to 0dBm | ±3.0 | dBm |
Rx Input Power | Internal | -15.0 to 0dBm | ±3.0 | dBm |
Recommended Circuit

Figure 3, Recommended Host Board Power Supply Circuit

Figure 4, Recommended Interface Circuit
Mechanical Dimensions

Figure 5, Mechanical Dimensions
Ordering information
Table 10. Ordering information
Part Number | Product Description |
PSFP10-SR | 850nm VCSEL, 10.3125Gbps, OM3 MMF 300m, 0°C ~ +70°C |
PSFP10-SRE | 850nm VCSEL, 10.3125Gbps, OM3 MMF 300m, -20°C ~ +85°C |
PSFP10-SRI | 850nm VCSEL, 10.3125Gbps, OM3 MMF 300m, -40°C ~ +85°C |
Warnings
Handling Precautions: This device is susceptible to damage as a result of electrostatic discharge (ESD). A static free environment is highly recommended. Follow guidelines according to proper ESD procedures.
Laser Safety: Radiation emitted by laser devices can be dangerous to human eyes.
Avoid eye exposure to direct or indirect radiation.
Exhibition Preview
FAQ
Listed below are answers to our most commonly asked questions. Don't see your question?Contact our customer service team. We would be glad to assist you.
What is an optical network terminal (ONT)? How does it differ from a regular modem?
What is the architecture of a fiber optic network (PON)?
What are the functions of the PON port and LAN port on an optical network terminal (ONT)?
Why does the optical network terminal need to register LOID/SN?
Optical modem dialing vs. router dialing: which is better?
How to determine whether the fiber optic signal is normal?
Recommend
Send enquiry
NOTE: Please leave your email, our professionals will contact you ASAP!