10Gbps BIDI 1270nm/1330nm &1330nm/1270nm 20Km
10Gbps BIDI 1270nm/1330nm &1330nm/1270nm 20Km
10Gbps BIDI 1270nm/1330nm &1330nm/1270nm 20Km
10Gbps BIDI 1270nm/1330nm &1330nm/1270nm 20Km
10Gbps BIDI 1270nm/1330nm &1330nm/1270nm 20Km
10Gbps BIDI 1270nm/1330nm &1330nm/1270nm 20Km
  • 10Gbps BIDI 1270nm/1330nm &1330nm/1270nm 20Km
  • 10Gbps BIDI 1270nm/1330nm &1330nm/1270nm 20Km
  • 10Gbps BIDI 1270nm/1330nm &1330nm/1270nm 20Km
  • 10Gbps BIDI 1270nm/1330nm &1330nm/1270nm 20Km
  • 10Gbps BIDI 1270nm/1330nm &1330nm/1270nm 20Km
  • 10Gbps BIDI 1270nm/1330nm &1330nm/1270nm 20Km

10Gbps BIDI 1270nm/1330nm &1330nm/1270nm 20Km

Olinkphotonics’OLSBxx1XL-CD10 series single mode transceiver is small form factor pluggable module for optical data communications such as 10GBASE-LR/LW defined by IEEE 802.3ae. It is with the SFP+ 20-pin connector to allow hot plug capability. The OLSBxx1XL-CD10 module is designed for single mode fiber and operates at a nominal wavelength of 1310nm or 1550nm; The transmitter section uses a multiple quantum well DFB, which is class 1 laser compliant according to International Safety Standard IEC-60825.The receiver section uses an integrated InGaAs detector preamplifier (IDP) mounted in an optical header and a limiting post-amplifier IC. The transceiver designs are optimized for high perform -ance and cost effective to supply customers the best solutions for telecommunication.

Category:

SFP optical module

Product Details

Product Features

Supports 9.95 to 10.3Gb/s bit rates

Simplex LC Connector

Hot pluggable SFP+ footprint

Uncooled 1270nm DFB transmitter, 1330nm PIN photo-detector 

Uncooled 1330nm DFB transmitter, 1270nm PIN photo-detector

Applicable for 10km SMF connection

Low power consumption, < 1W

Digital Diagnostic Monitor Interface  

Optical interface compliant to IEEE 802.3ae 10GBASE-LR 

Electrical interface compliant to SFF-8431  

Operating case temperature: 

Commerical:-20 to 75 °C 

Industrial:-40 to 85 °C 

 

Applications

10GBASE-LR at 10.3125Gbps

10GBASE-LW at 9.953Gbps   

Other optical link

 

Product Descriptions

Olinkphotonics’OLSBxx1XL-CD10 series single mode transceiver is small form factor pluggable module for optical data communications such as 10GBASE-LR/LW defined by IEEE 802.3ae. It is with the SFP+ 20-pin connector to allow hot plug capability. The OLSBxx1XL-CD10 module is designed for single mode fiber and operates at a nominal wavelength of 1310nm or 1550nm; The transmitter section uses a multiple quantum well DFB, which is class 1 laser compliant according to International Safety Standard IEC-60825.The receiver section uses an integrated InGaAs detector preamplifier (IDP) mounted in an optical header and a limiting post-amplifier IC. The transceiver designs are optimized for high perform -ance and cost effective to supply customers the best solutions for telecommunication.

 

Functional Diagram

                             

 

Absolute Maximum Ratings

Parameter

Symbol

Min.

Max.

Unit

Note

Supply Voltage

Vcc

-0.5

4.0

V

 

Storage Temperature

TS

-40

85

°C

 

Relative Humidity

RH

0

85

%

 

Note: Stress in excess of the maximum absolute ratings can cause permanent damage to the transceiver.

 

General Operating Characteristics

Parameter

Symbol

Min.

Typ

Max.

Unit

Note

Data Rate

DR

9.95

 

10.3125

Gb/s

 

Supply Voltage

Vcc

3.13

3.3

3.47

V

 

Supply Current

Icc5

 

 

285

mA

 

Operating Case Temp.

Tc

0

 

70

°C

 

TI

-40

 

80

 

 

Electrical Characteristics (TOP(C) = -20 to 75 , TOP(I) =-40 to 85 ,VCC = 3.13 to 3.47 V)

Parameter

Symbol

Min.

Typ

Max.

Unit

Note

Transmitter

Differential data input swing

VIN,PP

180

 

700

mVpp

1

Transmit Disable Voltage

VD

VCC-0.8

 

Vcc

V

 

Transmit Enable Voltage

VEN

Vee

 

Vee+0.8

Input differential impedance

Rin

 

100

 

Ω

 

Receiver

Differential data output swing

Vout,pp

300

 

850

mVpp

2

Output rise time and fall time

Tr, Tf

28

2.0

Vcc+0.3

Ps

3

LOS asserted

VLOS_F

VCC-0.8

 

Vcc

V

4

LOS de-asserted

VLOS_N

Vee

 

Vee+0.8

V

4

Notes:

1. Connected directly to TX data input pins. AC coupling from pins into laser driver IC.

2. Into 100Ω differential termination.

3. 20 – 80%. Measured with Module Compliance Test Board and OMA test pattern. Use of four 1’s and four 0’s sequence in the PRBS 9 is an acceptable alternative. 

4. LOS is an open collector output. Should be pulled up with 4.7kΩ – 10kΩ on the host board. Normal operation is logic 0; loss of signal is logic 1.

 

Optical Characteristics (TOP(C) = -20 to 75 , TOP(I) =-40 to 85 ,VCC = 3.13 to 3.47 V)

Parameter

Symbol

Min.

Typ

Max.

Unit

Note

Transmitter

Operating Wavelength

λ

1260

1270

1285

nm

 

1290

1330

1350

 

Ave. output power (Enabled)

PAVE

-6

 

0

dBm

1

Side-Mode Suppression Ratio

SMSR

30

 

 

dB

 

Extinction Ratio

ER

4

4.5

 

dB

 

RMS spectral width

Δλ

 

 

1

nm

 

Rise/Fall time (20%~80%)

Tr/Tf

 

 

50

ps

 

Dispersion penalty

TDP

 

 

3.2

dB

 

Relative Intensity Noise

RIN

 

 

-128

dB/Hz

 

Output Optical Eye

Compliant with IEEE 0802.3ae

Receiver

Operating Wavelength

λ

1530

1550

1565

nm

 

1260

1310

1355

 

Receiver Sensitivity(ER=4.5)

PSEN1

 

 

-12.6

dBm

2

Receiver Sensitivity(ER=6)

PSEN2

 

 

-13.1

dBm

2

Average Receive Power

PAVE

 

 

+0.5

dBm

 

Receiver Reflectance

Rrx

 

 

-12

dB

 

LOS Assert

Pa

-30

 

 

dBm

 

LOS De-assert

Pd

 

 

-17

dBm

 

LOS Hysteresis

Pd-Pa

0.5

 

4

dB

 

Notes:

1. Average power figures are informative only, per IEEE 802.3ae.

2. Measured with worst ER; BER<10-12; 231 – 1 PRBS.

 

Pin Defintion And Functions

Pin

Symbol

Name/Description

1

VEET [1]

Transmitter Ground 

 

2

Tx_FAULT [2]

Transmitter Fault 

 

3

Tx_DIS [3]

Transmitter Disable. Laser output disabled on high or open 

 

4

SDA [2]

2-wire Serial Interface Data Line

5

SCL [2]

2-wire Serial Interface Clock Line 

 

6

MOD_ABS [4]

Module Absent. Grounded within the module 

 

7

RS0 

Rate Select 0

8

RX_LOS [2]

Loss of Signal indication. Logic 0 indicates normal operation

9

RS1 [5]

Rate Select 1 

 

10

VEER [1]

Receiver Ground 

 

11

VEER [1]

Receiver Ground 

 

12

RD-

Receiver Inverted DATA out. AC Coupled 

 

13

RD+

Receiver DATA out. AC Coupled 

 

14

VEER [1]

Receiver Ground 

 

15

VCCR

Receiver Power Supply 

 

16

VCCT

Transmitter Power Supply 

 

17

VEET [1]

Transmitter Ground 

 

18

TD+

Transmitter DATA in. AC Coupled 

 

19

TD-

Transmitter Inverted DATA in. AC Coupled 

 

20

VEET [1]

Transmitter Ground 

 

Notes: 

1.Module circuit ground is isolated from module chassis ground within the module. 

2.should be pulled up with 4.7k – 10k ohms on host board to a voltage between 3.15Vand 3.6V. 

3.Tx_Disable is an input contact with a 4.7 kΩ to 10 kΩ pullup to VccT inside the module. 

4.Mod_ABS is connected to VeeT or VeeR in the SFP+ module. The host may pull this contact up to Vcc_Host with a resistor in the range 4.7 kΩ to10 kΩ.Mod_ABS is asserted “High” when the SFP+ module is physically absent from a host slot. 

 

Serial Interface for ID and DDM

The OLSBxx1XL-CD10 transceiver support the 2-wire serial communication protocol as defined in the SFP+ MSA. The standard SFP+ serial ID provides access to identification information that describes the transceiver’s capabilities, standard interfaces, manufacturer, and other information. Additionally, This SFP+ transceivers provide an enhanced digital diagnostic monitoring interface, which allows real-time access to device operating parameters such as transceiver temperature, laser bias current, transmitted optical power, received optical power and transceiver supply voltage. It also defines a sophisticated system of alarm and warning flags, which alerts end-users when particular operating parameters are outside of a factory set normal range.

The SFP MSA defines a 256-byte memory map in EEPROM that is accessible over a 2-wire serial interface at the 8 bit address 1010000X(A0h), so the originally monitoring interface makes use of the 8 bit address(A2h), so the originally defined serial ID memory map remains unchanged. The structure of the memory map is shown in Table1.

Table 1. Digital Diagnostic Memory Map (Specific Data Field Descriptions)

 

Digital Diagnostic Specifications

The OLSBxx1XL-CD10 transceivers can be used in host systems that require either internally or externally calibrated digital diagnostics. 

Parameter

Symbol

Units

Min.

Max.

Accuracy

Note

Transceiver temperature

DTemp-E

ºC

-45

+90

±5ºC

1,2

Transceiver supply voltage

DVoltage

V

2.8

4.0

±3%

 

Transmitter bias current

DBias

mA

0

127

±10%

3

Transmitter output power

DTx-Power

dBm

-8

+1

±2dB

 

Receiver average input power

DRx-Power

dBm

-17

+1

±2dB

 

Notes:

1.When Operating temp.=0~70 ºC,the range will be min=-5,Max=+75

2. Internally measured

3. The accuracy of the Tx bias current is 10% of the actual current from the laser driver to the laser

 

Typical Interface Circuit

 

Recommended power supply filter

Note: 

Inductors with DC resistance of less than 1Ω should be used in order to maintain the required voltage at the SFP input pin with 3.3V supply voltage. When the recommended supply filtering network is used, hot plugging of the SFP transceiver module will result in an inrush current of no more than 30 mA greater than the steady state value

 

Package Dimensions 

 

 

 

 

 

 

 

 

 

 

 

 

 

Ordering Information

Part Number

Description

 

SFP+Bidi,9.95 to 10.3Gb/s, 1270/1330nm, 10km, -20~75, with DDM

 

SFP+Bidi,9.95 to 10.3Gb/s, 1330/1270nm, 10km, -20~75, with DDM

 

SFP+Bidi,9.95 to 10.3Gb/s, 1270/1330nm, 10km, -40~85, with DDM

 

SFP+Bidi,9.95 to 10.3Gb/s, 1330/1270nm, 10km, -40~85, with DDM

Exhibition Preview

Production Environment
Production Environment
Production Environment
Production Environment
Production Environment
Production Environment
Production Environment
Production Environment

FAQ

Listed below are answers to our most commonly asked questions. Don't see your question?Contact our customer service team. We would be glad to assist you.

What is an optical network terminal (ONT)? How does it differ from a regular modem?

An optical network unit (ONU) is an end device in a fiber optic network that converts optical signals transmitted via fiber optics into electrical signals (for use by routers, computers, and other devices), and vice versa.

What is the architecture of a fiber optic network (PON)?

Fiber optic networks typically use a passive optical network (PON) architecture, which is divided into three layers

What are the functions of the PON port and LAN port on an optical network terminal (ONT)?

PON port (fiber optic interface): Connects to the fiber optic cable entering the home and receives optical signals (usually SC/APC interface, blue square head).

Why does the optical network terminal need to register LOID/SN?

LOID (Logical Identifier) or SN (Serial Number) is the credential used by operators to bind user identities, and is used for OLT authentication of optical modems.

Optical modem dialing vs. router dialing: which is better?

Ordinary users: Optical modem dialing. Game/NAS users: Switch to bridge mode and dial up using a high-performance router.

How to determine whether the fiber optic signal is normal?

Check the optical modem indicator lights Log in to the optical modem management interface: Check the optical power (unit: dBm)

Send enquiry

NOTE: Please leave your email, our professionals will contact you ASAP!