Email: demi@gl-com.com
GL-X8016U-RP 16GE POE ONU
Category:
MDU
Product Details
Product overview
X8016U-RP is an EPON upstream, 16*1000M electrical ports with POE power supply function, a POE ONU specially designed for security. The ONU can directly provide users with IP data access. Based on the mature, stable and cost-effective EPON technology,it provides a PON interface and 16 100/1000M adaptive electrical interfaces. It adopts single fiber wavelength division multiplexing technology (downlink 1490nm, uplink 1310nm), only one optical fiber is connected to the OLT, the maximum transmission distance can reach 20 kilometers, and it supports the power-down reporting function. The 16 POE electrical ports have the function of automatically detecting and identifying PD devices that meet the IEEE 802 af/at standard and powering them, so there
is no need to worry about damaging PoE or non-PoE devices of private standards. It is an ideal choice for economical use of PoE to deploy wireless access points (AP) and IP-based network surveillance cameras for small business networks. It can effectively solve the problems of cumbersome maintenance, wireless coverage, terminal equipment power supply, and security monitoring engineering chief, saving engineering costs to the maximum.
Product feature
Meet the technical requirements of IEEE802.3ah-2005 and CTC EPON equipment
Support symmetrical 1Gbit/s rate
Support 1 LLID, support two-way FEC, support RS (255,239) FEC codec
Support downstream three-fold agitation, support AES128 decryption function
Support synchronous Ethernet function, support SBA and DBA bandwidth allocation
Support Dying-Gasp detection and reporting
Support mainstream ONU detection
Two-way wire-speed forwarding of Layer 2 data services, supporting 1K MAC address tables in bridge mode >Support 802.3, 802.1Q Tag/Untag Ethernet frame, support QinQ
Support flexible tag processing, compatible with CTC2.1, TR156 requirements
Support energy saving in line with CTC2.1 standard
Support L2, L3 (IPv4/6) multicast forwarding, support multiple forwarding methods, including: DMAC, DMAC +VLAN, DIP, IP+SIP,DIP+VLAN, DIP+SIP+VLAN
Support QOS function
Adopt single fiber wavelength division multiplexing technology (downlink 1490nm, uplink 1310nm), only need one optical fiber to connect with OLT, the transmission distance can reach 40 kilometers
Installation and maintenance are easy to do, support local/remote multiple methods for management configuration and software upgrades, and cooperate with the central office OLT to achieve remote fault diagnosis and location functions, greatly reducing maintenance workload
The 100M electrical port supports power supply through wireless access points (AP) and network surveillance cameras (sur veillance cameras) via Category 5 Ethernet cables
POE power port supports IEEE802.3af/at standard PD equipment
Ultra-long-distance data transmission and power supply, with a distance of up to 100 meters, saves power lines, and can be flexibly installed for wireless AP and network monitoring equipment engineering
Store-and-forward exchange mechanism
Intelligent power supply, the lowest power consumption, to ensure the power demand of the PD
With power circuit protection function to protect the safety of back-end equipment
The zero configuration characteristic power is automatically supplied to the adaptive device
Fanless silent design, energy saving and environmental protection
The machine is designed with hanging ears, which can be flexibly placed in positions such as switches and walls
Support loop detection
Support port no connection power saving function
Technical parameters
Model | X8016U-RP | ||
| Input voltage | AC100-240V 50-60Hz | |
Power consumption | The machine itself consumes:<15W Total power consumption:<250w | ||
Port parameters | network port | 1~16 downlink electric port:10/100/1000Mbps 1 uplink PON port: 1.25Gbps/SC | |
Transmission distance | 1~16 downstream POE network port:100m CCTV ON downstream support 250m upstream network port:<100m upstream optical port 0-120KM optional | ||
Transmission medium | 1-16 downstream network port:Cat5e/6 standard UTP network cable upstream optical port:fiber/SFP | ||
POE standard | Comply with IEEE 802.3af/at international standard, single port maximum power supply 30W | ||
POE power supply mode | End jumper | ||
POE power supply | Single POE port≤30W,Whole machine<250W | ||
Exchange parameters | Network standard | IEEE802.3i,IEEE802.3u,IEEE802.3ab,IEEE802.3z,IEEE802.3x,IEEE802.3az,IEEE802.1Q(VLAN), IEEE 802.1w(RSTP)、 IEEE 802.3af/at | |
Backplane bandwidth | 7.2Gbps | ||
Forwarding method | Store and forward | ||
Forwarding rate | 10Mbps:14880pps, 100Mbps:148800pps | ||
Packet data cache | 5.4M | ||
MAC address table | 4K | ||
Status Indicator | Power Indicator | 1 indicating power supply (green) | |
Fiber optic indicator | GF port green light | ||
Ultra long-distance transmission indicator | 1 indicator CCTV (green) | ||
POE power port LED | PoE status indication 16 RJ45 yellow lights | ||
Network data port LED | Data status indication 16 RJ45 green lights | ||
Switch | Dial switch | Default state CCTV state,1-16 port isolation and speed down to 10M,Data and power transmission distance 250 meters Vlan mode,Downstream port isolation | |
Protection level | Lightning protection for communication ports | 4KV executive standard:IEC61000-4-5 | |
Environment specification | Operating temperature | -20℃~55℃ | |
Storage temperature | -40℃~70℃ | ||
Humidity (non-condensing) | 5~95% | ||
Physical specifications | Size | 330 x 205 x 44.5mm | |
Color | Black | ||
Weight | 1.7kg | ||
Reliability | Mean time between failures | >50000h | |
Advantages of PON in monitoring applications
1. Reduce the cost of network construction, which is lower than traditional solutions. Traditional video surveillance systems mostly use video coaxial cables or Ethernet cables. For long-distance transmission, they use video optical transceivers+optical cables+video optical transceivers. However, with PON technology, one ONU can connect multiple IP cameras within a hundred meters range through Ethernet cables, greatly reducing the number of devices.
2. The overall network stability has been greatly improved. PON systems generally consist of splitters and optical fibers, with glass being the main component and having a long service life; Without active devices, common faults of active devices such as power outages, lightning strikes, and damage caused by overcurrent and overvoltage are avoided. The network has high reliability and significantly reduces maintenance costs.
3. The Yuncheng video surveillance network has a wide coverage range: it can provide 0.5-20KM long-distance video signal access, basically covering the range of medium-sized urban areas. The vast majority of cameras in the city can directly transmit image information to the local video surveillance platform through optical networks.
4. Large transmission bandwidth: The bandwidth of each ONU can be dynamically adjusted between 2M-1Gbps, and the average upstream bandwidth of each ONU is around 30M, which means that one OLT port (the backbone fiber can carry 100 video streams).
5. Flexible networking: The networking model is not limited, and different combinations of splitters can be used to flexibly form chain, tree, and star networks. The networking method can be adjusted according to the different geographical locations of the cameras and the different needs of customers to meet the rational configuration of network resources.
6. System expansion is simple. PON is transparent to a certain extent to the transmission system used, and the expansion operation on the transmission side is convenient when the number of monitoring points is needed.
Exhibition Preview
FAQ
Listed below are answers to our most commonly asked questions. Don't see your question?Contact our customer service team. We would be glad to assist you.
What is an optical network terminal (ONT)? How does it differ from a regular modem?
What is the architecture of a fiber optic network (PON)?
What are the functions of the PON port and LAN port on an optical network terminal (ONT)?
Why does the optical network terminal need to register LOID/SN?
Optical modem dialing vs. router dialing: which is better?
How to determine whether the fiber optic signal is normal?
Recommend
Send enquiry
NOTE: Please leave your email, our professionals will contact you ASAP!