L3 Managed Ethernet Switch S5630-24TS4SX
L3 Managed Ethernet Switch S5630-24TS4SX
L3 Managed Ethernet Switch S5630-24TS4SX
L3 Managed Ethernet Switch S5630-24TS4SX
  • L3 Managed Ethernet Switch S5630-24TS4SX
  • L3 Managed Ethernet Switch S5630-24TS4SX
  • L3 Managed Ethernet Switch S5630-24TS4SX
  • L3 Managed Ethernet Switch S5630-24TS4SX

L3 Managed Ethernet Switch S5630-24TS4SX

The S5630-24TS4SX switch is a high-performance 1G fiber combo switch developed by our company. It features advanced hardware design and a hot-swappable power supply for redundancy. This switch supports up to 24*1G combo ports, along with 4*10GE uplink ports. It offers full-port L2/L3 wire-speed forwarding, IPv6 support, and a range of business features, including ACL policies, and network security. The S5630-24TS4SX provides the highest 10 Gigabit port density and maximum switching capacity in its class, supporting wire-speed forwarding on all ports. It also accommodates flexible access for both 1GE and 10GE connections and automatically recognizes the type of optical module installed, maximizing user investment protection and ensuring flexibility. Additionally, designed for high-density and high-bandwidth applications, this switch meets the demands of next-generation enterprise networks, data centers, and metropolitan area networks. It is suitable for network operators, campus Ethernet aggregation or access layers, data center access layers, and small to medium-sized enterprise core layers, offering comprehensive server access solutions for data centers.

Category:

Ethernet switch (core layer)

Product Details

Product Overview

The S5630-24TS4SX switch is a high-performance 1G fiber combo switch developed by our company. It features advanced hardware design and a hot-swappable power supply for redundancy. This switch supports up to 24*1G combo ports, along with 4*10GE uplink ports. It offers full-port L2/L3 wire-speed forwarding, IPv6 support, and a range of business features, including ACL policies, and network security.

The S5630-24TS4SX provides the highest 10 Gigabit port density and maximum switching capacity in its class, supporting wire-speed forwarding on all ports. It also accommodates flexible access for both 1GE and 10GE connections and automatically recognizes the type of optical module installed, maximizing user investment protection and ensuring flexibility.

Additionally, designed for high-density and high-bandwidth applications, this switch meets the demands of next-generation enterprise networks, data centers, and metropolitan area networks. It is suitable for network operators, campus Ethernet aggregation or access layers, data center access layers, and small to medium-sized enterprise core layers, offering comprehensive server access solutions for data centers.

 

Device Brief Information

S5630-24TS4SX

24*1G Combo Port

4*10G SFP+ port

128Gbps Switching capacity

Size: 440×368×44mm 19” Rack-mount

AC+AC (or AC+DC,or DC+DC) power supply  

AC: 100~240V; 47/63Hz

DC: -20V~-60V

2*Modular FAN supply

 

Key Features 

Equipment Stability

  • Support IPv4/IPv6 dual protocol stack platform based on Linux operating system
  • Support multiple link redundancy and network redundancy protocols such as STP / RSTP / MSTP / ERPS / LACP 

Carrier-level equipment stability

  • Based on Linux operating system, support IPv4/IPv6 dual protocol stack platform
  • Support multiple link redundancy and network redundancy protocols such as STP/RSTP/MSTP/ERPS/LACP

Stackable

  • Support Combine the processing power of multiple switches into a single logical device.
  • Support When a switch in the stack system fails, traffic can be automatically switched to other switches, network availability and redundancy.
  • Support Stacking simplifies the management process. Administrators only need to manage one logical device.

Perfect safety mechanism

  • Support ACL security filtering mechanism, which can provide security control functions based on MAC, IP, L4 port
  • Support ARP attack automatic protection and user blocking functions
  • Support DHCP attack automatic protection based on Mac Address and user blocking functions
  • Support DHCP-snooping/IP-source-Guard/802.1X and other security features
  • Support link protection functions such as BFD, FlexLink, LACP 
  • Support remote loop detection function
  • Support remote user authentication based on Tacacs+, Radius, and Local user authentication

Powerful QoS capabilities

  • Support port speed and flow speed limit function
  • Support classification based on service flow and Qos flow control function
  • Support queue scheduling algorithms such as SP/WRR/SP+WRR
  • Support port-based and service flow-based mirroring functions

Enhanced multi-service capabilities

  • Support DHCP Server and DHCP Relay

Rich routing protocol

  • Support static route
  • Support dynamic route such as RIP, OSPF, BGP,
  • Support IPV4/IPV6 dual protocol stack, support RIPng、OSPFv3

Simple and easy-to-use network management function

  • Support CLI based on RS232 serial port, Telnet and SSHv2
  • Support WEB-based configure operation management, support SNMP V1/V2/V3
  • Support remote upgrade or equipment through FTP and TFTP

 

Hardware Specifications

Attributes

S5630-24TS4SX

Port

24*100M/1G Combo; 4*1G SFP/10G SFP+

Chip Solution

98DX3510(Marvell)

Exchange Capacity

128Gbps

Packet Forwarding Rate

95.24Mpps

Memory and Storage

Memory: 1GB; Storage: 8GB

MAC Address

32K

Packet Buffer

24Mbit

Power

AC: 100~240V; 47/63Hz

DC: -20V ~ -60V

Power Consumption

Full load ≤63W

Weight

≤6.8kg (AC+DC)

Dimensions (W*H* D)

440×368×44mm

Environment

Working Temperature: -10℃~50℃

Storge Temperature: -40℃~70℃

Relative Humidity :5%~95%, non-condensing

 

Panel view

 

 

 

 

 

 

 

 

 

 

 

 

 

Label

Connector Type

Connector Description

1G 1-24

Combo port

Connect the user port

1G/10G 1-4

SFP+

Connect to external uplink equipment

USB

USB2.0/3.2

Connecting peripherals for uploading and downloading configuration

CONSOLE

RJ45

The software debug port

MGMT

RJ45

The out-band management port

 

LED indicator

LEDs/Buttons

Color

Function

Description

PWR1 (left)
PWR2 (right)

Green

Power status

ON

The AC/DC power module is normal.

OFF

The AC/DC power module faulty or unavailable

FAN1(left)
FAN2(right)

Green

Fan running status

ON

FAN is running normally.

OFF

FAN is running abnormally.

SYS

Green

System running status

Green OFF

The device is not running or power off.

Green Flash

The device is running normally.

USB

Green

USB flash insertion status

ON

Insert flash (Fat32)

OFF

NO Insert flash (Fat32)

MGMT

Green

Port status

ON

The link is properly connected (link up) and in action

OFF

The link is interrupted (link down).

GE/SFP Port

Green

Port status

ON/Flash

The link is properly connected (link up) and in action Works in gigabit mode.

 

OFF

The link is interrupted (link down).

Orange

ON/Flash

The link is properly connected (link up) and in action Works in 10/100Mbps mode.

 

Plug-In Units

Power Supply Unit (PSU)

On the rear panel of the switch, there are two slots for Power Supply Unit (PSU).  The mounting slots can be equipped with DC or AC type PSUs.  The different type of PSUs can be equipped into the switch.  The below shows AC and DC type of power supply modules Two PSUs, for supplying redundancy, dual PSUs have to be installed at a system.

The power supply unit (PSU) feeds the proper power voltage to the base board of switch.  Two PSUs are possible to be mounted into rear side of the chassis and it can be DC or AC type of PSU.  Therefore, you need to decide to choose proper power supply unit according to installation environment.

The power connector (AC and DC type) for main power supply is located on the rear panel of the PSU.  For redundant power feeding, the second PSU has to be used.

The below shows the electrical characteristics of the switch:

Characteristic

S5630-24TS4SX

Nominal DC power supply

DC: -20V ~ -60V/8A MAX

Nominal AC power supply

AC: 100~240V; 47/63Hz

FAN

The temperature starts at 0 degrees and rotates at 30% speed (about 3900 RPM), and the speed increases by 0.78%x13000 rpm for every 1 degree increase.

AC Rated power of power supply

114W

DC Rated power of power supply

114W

          

FAN Unit

The switch provides 2 fan unit slots on the rear panel. This plug-in unit internally consists of 2 fans. User can insert fan unit to a fan slot by slowly adjusting them to fit into the slot guid-ance. The air flows from the front side inlet to the rear side outlet.

 

Characteristic

S5630-24TS4SX

 

FAN

The temperature of the switch chip attachment starts at 30 degrees and rotates at 30% speed (about 3600 RPM). For every 1 degree increase, the speed increases by 1.57%x12000 rpm.

 

Software Specifications

Attributes

S5630-24TS4SX

VLAN

Support 4K VLAN 

Support VLAN based on port, MAC and protocol

Support dual Tag VLAN, 

Access/Trunk/Hybrid

Ethernet

Ethernet interface operating modes

Ethernet interface operating rates

Jumbo Frame

Port enable/disable

Port based storm-control

Unknow-unicast/unknow-multicast/broadcast storm-control

Port-isolate

Stackable

Support Sacking of 8 units through a single ip address.

Support ‌Unified management.‌

Support Redundancy mechanism.

Support High speed interconnect.

VXLAN

Support VXLAN uses MAC in UDP encapsulation

Support VMS can move between different Layer 2 network domains.

‌Support VNI is used to isolate different virtual networks to ensure that network traffic of different tenants is isolated ‌.

Support Enable virtual machine packets to communicate across different subnets and data centers; ‌

MAC

Support static MAC address setting 

Support black hole MAC address filtering 

Support port MAC address limit

Automatic learning and aging of MAC addresses

ARP

Static and dynamic ARP entries

Aging of ARP entries

ARP-Proxy

Port Control

Support two-way bandwidth control 

Support port storm suppression 

Support 9K Jumbo ultra-long frame forwarding

Port Aggregation

Support static link aggregation 

Support dynamic LACP 

Each aggregation group supports a maximum of 8 ports

LAG load balance(SIP/DIP/SMAC/DMAC)

Mirroring

Supports multi-port mirroring analysis

Service flow-based image analysis

ACL

Support standard and extended ACL 

Support ACL policy based on time period 

Provide MAC, IP, L4 port and port level security control functions

QoS

Traffic classification based on COS/DSCP (simple classification)

Traffic classification based on ACL (complex classification)

Traffic classification based on inner header of the tunnel packets

Queue scheduling

Remark the priority fields (COS/DSCP) of the packet based on ACL

Flow redirection

Flow mirror

Traffic policing based on direction(in/out) of Port

Traffic policing based on direction(in/out) of VLAN

Traffic policing based on direction(in/out) of flow

Traffic policing based on direction(in/out) of aggregated flow

SP(Strict Priority)scheduling

WRR(Weighted Round Robin)scheduling

SP + WRR mixed scheduling

Safety

Support user hierarchical management and password protection 

Support IEEE 802.1X authentication 

Support Radius & TACACS+ authentication 

Support MAC address learning limit, support black hole MAC function 

Support port isolation 

Support broadcast message rate suppression 

Support IP Source Guard Support ARP flood suppression and ARP spoofing protection 

Layer 3

Support ARP learning and aging

Support IPv4/IPv6 static route

Support dynamic route RIP/OSPF/BGP

Support IPv4/IPv6 dual-stack platform

Support VRRP、CLI、Telnet、WEB、SNMP V1/V2/V3、SSHv2 mode

Terminal Services

Configurations through CLI

Console Terminal service

Maintenance

Per-module Debug features

CPU usage display and alarm

Memory usage display and alarm

Device temperature、PSU、FAN、status display and alarm

User operation logs

Management of logs, alarms, and debugging information

Detailed Diagnostic-information collection

Manual /Schedule reboot

Reboot Information logging

Ping

IPv6 Ping

Traceroute

Port/Flow/Remote mirror

To CPU/From CPU packets statistics

Time configuration

Timezone

System Security

SSHv1/v2

RADIUS

TACACS+

Authentication

Accounting

Port based dot1x

MAC based dot1x

MAC/IP ACL

Port/VLAN/L4-Port ACL

IP Source Guard

Limitation on MAC address learning on interface

Rate limit

CPU Traffic Limit

CLI/WEB/SNMP/Telnet/SSH filtering

Spanning-Tree

Rapid Spanning-Tree Protocol

Multi-instance Spanning-Tree Protocol

Network

Management

DHCP Server

DHCP Relay

DHCP Snooping

DHCP Option60

DHCP Option82

DHCP Option66

DHCP Option120

SNTP Simple Network Time Protocol)

LLDP

Configuration Management

Inband management interface and configuration

Outband management interface and configuration 

Privileged user priority and privileged commands

Network management based on SNMPv1/v2c/v3

Public and private MIB

Public and private Trap

Configuration and management based on WEB

Restore factory default configuration

File system

Upload and download files through FTP or TFTP

Upload and download files through Xmodem

System Management

Support FTP, TFTP file upload and download

Support SNTP

Support LLDP neighbor device discovery protocol

Support RFC1213 SNMP network management 

Support Ping and Traceroute

Supports configuration management based on WEB pages

Upgrade

Upgrade with the local image file

Upgrade with the remote TFTP server

Online upgrade Uboot

 

Connector Specifications

The switch provides standardized interfaces, thus facilitating rapid and trouble-free integration into the existing network infrastructures.

Network Interfaces

The switch optical interface ports for SFP/SFP+ modules and below table is available SFP/SFP+ module list.

Index

SFP/SFP+ Module Description

1

- Wavelength: 850 nm / Distance: 550 m / Mode: multi-mode

- Connector: LC / Data rate: 1.25Gbit/s / Core type: Dual Core

- Operating Temperature: 0 °C - 70 °C

2

-. Wavelength: 1310nm / Distance: 5km / Mode: single-mode

-. Connector: LC / Data rate: 1.25Gbit/s / Core type: Dual Core

-. Operating Temperature: 0 °C – 70 °C

3

- Wavelength: 1310 nm / Distance: 10 km / Mode: single-mode

- Connector: LC / Data rate: 1.25 Gbit/s / Core type: Dual Core

- Operating Temperature: 0 °C – 70 °C

4

- Wavelength: 1310 nm / Distance: 15 km / Mode: single-mode

- Connector: LC / Data rate: 1.25 Gbit/s / Core type: Dual Core

- Operating Temperature: 0 °C – 70 °C

5

- Wavelength: 1310 nm / Distance: 20 km / Mode: single-mode

- Connector: LC / Data rate: 1.25 Gbit/s / Core type: Dual Core

- Operating Temperature: 0 °C - 70 °C

6

- Wavelength: 1310 nm / Distance: 40 km / Mode: single-mode

- Connector: LC / Data rate: 1.25 Gbit/s / Core type: Dual Core

- Operating Temperature: 0 °C - 70 °C

7

- Wavelength: 850nm / Distance: 300m / Mode: Multimode

- Connector: LC / Data rate: 10.3125 Gbit/s / Core type: Dual Core

- Operating Temperature: 0°C ~ 70 °C

- 10GBASE-SR (10G)

8

- Wavelength: 850nm / Distance: 300m / Mode: Multimode

- Connector: LC / Data rate: 10.3125 Gbit/s / Core type: Dual Core

- Operating Temperature: 0°C ~ 70 °C

- 1000BASE-SX (1G), 10GBASE-SR (10G)

9

 - Wavelength: 1310nm / Distance: 10Km / Mode: Single mode

 - Connector: LC / Data rate: 10.3125 Gbit/s / Core type: Dual Core

 - Operating Temperature: 0°C ~ 70 °C

 - 10GBASE-LR (10G)

10

 - Wavelength: 1550nm / Distance: 40Km / Mode: Single mode

 - Connector: LC / Data rate: 10.3125 Gbit/s / Core type: Dual Core

 - Operating Temperature: 0°C ~ 70 °C

 - 10GBASE-ER (10G)

11

- Wavelength: 1310nm / Distance: 70Km / Mode: Single mode

- Connector: LC / Data rate: 10.3125 Gbit/s / Core type: Dual Core

- Operating Temperature: 0°C ~ 70 °C

- 10GBASE-ZR (10G)

 

Purchase Info

Product Name

Product Description

S5630-24TS4SX

24*1G Combo;4*10GE SFP+

Exhibition Preview

Production Environment
Production Environment
Production Environment
Production Environment
Production Environment
Production Environment
Production Environment
Production Environment

FAQ

Listed below are answers to our most commonly asked questions. Don't see your question?Contact our customer service team. We would be glad to assist you.

What is an optical network terminal (ONT)? How does it differ from a regular modem?

An optical network unit (ONU) is an end device in a fiber optic network that converts optical signals transmitted via fiber optics into electrical signals (for use by routers, computers, and other devices), and vice versa.

What is the architecture of a fiber optic network (PON)?

Fiber optic networks typically use a passive optical network (PON) architecture, which is divided into three layers

What are the functions of the PON port and LAN port on an optical network terminal (ONT)?

PON port (fiber optic interface): Connects to the fiber optic cable entering the home and receives optical signals (usually SC/APC interface, blue square head).

Why does the optical network terminal need to register LOID/SN?

LOID (Logical Identifier) or SN (Serial Number) is the credential used by operators to bind user identities, and is used for OLT authentication of optical modems.

Optical modem dialing vs. router dialing: which is better?

Ordinary users: Optical modem dialing. Game/NAS users: Switch to bridge mode and dial up using a high-performance router.

How to determine whether the fiber optic signal is normal?

Check the optical modem indicator lights Log in to the optical modem management interface: Check the optical power (unit: dBm)

Send enquiry

NOTE: Please leave your email, our professionals will contact you ASAP!