L3 Managed Ethernet Switch S5710 Series
  • L3 Managed Ethernet Switch S5710 Series

L3 Managed Ethernet Switch S5710 Series

The S5710 series switch is a layer 3 Ethernet switch, owns 10 gigabit uplink for enterprise networks and operator customers, which can also meet the needs of cost-effective gigabit access. This device uses a high-performance & low-power network processor, provides gigabit line-speed forwarding performance, supports green Ethernet line sleep capability, which has the lowest power consumption of the same-level equipment in the industry as well. Supports powerful QoS and ACL functions, IP+MAC+ Security features such as port binding support service flow classification and packet priority marking. The product includes an elastic stacking function, which allows multiple devices to be virtualized into a single logical entity. This not only facilitates the expansion of ports and switching capacity but also enables unified management, upgrades, and maintenance across devices. It can also support static data packet sampling, SFLOW function, multi-port mirroring analysis function, static and flexible QinQ function, strategy-based IPV4/6 unicast routing, and Flexible forwarding strategy.

Category:

Ethernet switch (core layer)

Product Details

Product Overview

The S5710 series switch is a layer 3 Ethernet switch, owns 10 gigabit uplink for enterprise networks and operator customers, which can also meet the needs of cost-effective gigabit access. This device uses a high-performance & low-power network processor, provides gigabit line-speed forwarding performance, supports green Ethernet line sleep capability, which has the lowest power consumption of the same-level equipment in the industry as well. Supports powerful QoS and ACL functions, IP+MAC+ Security features such as port binding support service flow classification and packet priority marking. 

The product includes an elastic stacking function, which allows multiple devices to be virtualized into a single logical entity. This not only facilitates the expansion of ports and switching capacity but also enables unified management, upgrades, and maintenance across devices. It can also support static data packet sampling, SFLOW function, multi-port mirroring analysis function, static and flexible QinQ function, strategy-based IPV4/6 unicast routing, and Flexible forwarding strategy.

 

Device Brief Information 

S5710-12TX

8* 10/100/1000M Base-T RJ45 port

4* SFP/10G SFP+ port

AC input: 100~240V,50/60Hz

11”1U (270*180*44mm) 

S5710-28TX

24* 10/100/1000M Base-T RJ45 port

4* SFP/10G SFP+ port

AC input: 100~240V,50/60Hz

19”1U (440*210*44mm)

S5710-28TP

24* 10/100/1000M Base-T PoE RJ45 port

4* SFP/10G SFP+ port

PoE budget: 400W (802.3af/at)

AC input: 100~240V,50/60Hz

19”1U (440*260*44mm)

S5710-54TX

48* 100/1000M Base-T RJ45 port

6* SFP/10G SFP+ port

AC input: 100~240V,50/60Hz

DC: 40V~60V

19”1U (440*290*44mm)

 

Key Features 

Carrier-level equipment stability

Based on Linux operating system,support IPv4/IPv6 dual protocol stack platform

Support multiple link redundancy and network redundancy protocols such as STP/RSTP/MSTP/LACP

Stacking Capabilities

Support Stacking of 8 units through a single IP address

Support ‌Unified management‌

Support Redundancy mechanism

Support High speed interconnect

Perfect safety mechanism

Support link protection functions FlexLink, LACP 

Support remote loop detection function

Support remote user authentication based on Tacacs+, Radius, and Local user authentication

Powerful QoS capabilities

Support port speed and flow speed limit function

Support classification based on service flow and Qos flow control function

Support queue scheduling algorithms such as SP/WRR/SP+WRR

Support port-based and service flow-based mirroring functions

Rich management protocols

Support easy-to-use network management function

Support CLI based on RS232 serial port, Telnet and SSHv2

Support WEB-based configure operation management, support SNMP V1/V2/V3

Support remote upgrade or equipment through FTP and TFTP

 

Hardware Specifications

Attributes

S5710-12TX

S5710-28TX

S5710-28TP

S5710-54TX

Port

8*10/100/1000M/ Ethernet port

4 *10G SFP+

24*10/100/1000M/ Ethernet port

4 *10G SFP+

24*10/100/1000M/ Ethernet port/POE

4 *10G SFP+

48*10/100/1000M/ Ethernet port

6 *10G SFP+

Chipset

RTL9301

RTL9311

Switching Capacity

96Gbps

128Gbps

216Gbps

Forwarding Rate

71.43Mpps

95.24Mpps

160.71Mpps

MAC

16K

32K

Multicast

1K

4K

Packet Buffer

12Mbit

16Mbit

ARP Table

2K

8K

Routing Table

512

12K

PoE Budget

N/A

N/A

415W(af/at)

N/A

Memory and Storage

Memory512MB, Storage:32MB

Power Supply

AC: 100~240V 50/60Hz;

Power Consumption

Idle ≤10W

Full load ≤20W

Idle ≤13W

Full load ≤30W

Idle ≤15W

Full load ≤450W 

Idle ≤25W

Full load ≤53W

Weight

1.6kg

2.6kg

4.2Kg

4.2kg

Dimensions

(WxDxH)

270X180X44mm

440X210X44mm

440X260X44mm

440×290×44mm

Temperature

Working Temperature:-10℃~50℃; Storage Temperature:-40℃~70℃

Humidity

Relative Humidity: 5%~95%, non-condensing

 

Panel view

S5710-12TX
S5710-28TX
S5710-28TP
S5710-54TX

 

LED indicator

LEDs/Buttons

Color

Function

Description

PWR 

Green

Power status

ON

The AC power module is normal.

OFF

The AC power module faulty or unavailable.

SYS

Green

System running status

Green OFF

The device is not running or power off.

Green Flash

The device is running normally.

ALARM

RED

Hardware state

ON

The fan or power module is abnormal

OFF

Components working properly.

POE MAX

Green

Power Threshold

ON

Maximum power supplied by POE.

OFF

The POE power supply indicates the normal range.

GE/SFP Port

Green

Port status

ON/Flash

The link is properly connected (link up) and in action Works in Gigabit mode.

 

OFF

The link is interrupted (link down).

Orange

ON/Flash

The link is properly connected (link up) and in action Works in 10/100Mbps mode.

POE

Green

PD status

ON

The POE port is connected to the PD device and starts to supply power.

OFF

No PD is connected to the device.

 

Plug-In Units

Power Supply Unit (PSU)

The S5710 series devices are equipped with a built-in AC power module and provide an AC power port on the back of the device.

The below shows the electrical characteristics of the switch:

Characteristic

S5710 Series

Nominal AC power supply

AC: 100~240V; 47/63Hz

FAN Unit

The fans of the device run according to the power of the device environment. A built-in fan group is installed on the side of the chassis. The fan group can be as follows:

Characteristic

FAN

S5710-12TX

0*FAN

S5710-28TX

1*FAN

S5710-28TP

3*FAN

S5710-54TX

2*FAN

 

 

Software Specifications

Attributes

S5710 Series

VLAN

Support 4K VLAN 

Support VLAN based on port, MAC and protocol

Support dual Tag VLAN, 

Access/Trunk/Hybrid

Ethernet

Ethernet interface operating modes

Ethernet interface operating rates

Jumbo Frame

Port enable/disable

Port based storm-control

Unknow-unicast/unknow-multicast/broadcast storm-control

Port-isolate

Stackable

Support Stacking of 8 units through a single IP address

Support ‌Unified management‌

Support Redundancy mechanism

Support High speed interconnect

MAC

Support static MAC address setting 

Support black hole MAC address filtering 

Support port MAC address limit

Automatic learning and aging of MAC addresses

ARP

Static and dynamic ARP entries

Aging of ARP entries

ARP-Proxy

Port Control

Support two-way bandwidth control 

Support port storm suppression 

Support 9K Jumbo ultra-long frame forwarding

Port Aggregation

Support static link aggregation 

Support dynamic LACP 

Each aggregation group supports a maximum of 8 ports

LAG load balance(SIP/DIP/SMAC/DMAC)

Mirroring

Supports multi-port mirroring analysis

Service flow-based image analysis

ACL

Support standard and extended ACL 

Support ACL policy based on time period 

Provide MAC, IP, L4 port and port level security control functions

QoS

Traffic classification based on COS/DSCP (simple classification)

Traffic classification based on ACL (complex classification)

Traffic classification based on inner header of the tunnel packets

Queue scheduling

Remark the priority fields (COS/DSCP) of the packet based on ACL

Traffic policing based on direction(in/out) of Port

Traffic policing based on direction(in/out) of VLAN

Traffic policing based on direction(in/out) of flow

Traffic policing based on direction(in/out) of aggregated flow

SP(Strict Priority)scheduling

WRR(Weighted Round Robin)scheduling

SP + WRR mixed scheduling

Safety

Support Radius & TACACS+ authentication 

Support port isolation 

Support broadcast message rate suppression 

Support IP Source Guard Support ARP flood suppression and ARP spoofing protection 

Layer 3

Support ARP learning and aging

Support IPv4static route

Support dynamic route RIP/OSPF

Support IPv4/IPv6 dual-stack platform

Support CLI、Telnet、WEB、SNMP V1/V2/V3、SSHv2 mode

Terminal Services

Configurations through CLI

Console Terminal service

Maintenance

Per-module Debug features

CPU usage display and alarm

Memory usage display and alarm

User operation logs

Management of logs, alarms, and debugging information

Manual reboot

Reboot Information logging

Ping

IPv6 Ping

Traceroute

To CPU/From CPU packets statistics

Time configuration

Timezone

System Security

SSHv1/v2

RADIUS

TACACS+

MAC/IP ACL

Port/VLAN/L4-Port ACL

IP Source Guard

Limitation on MAC address learning on interface

Rate limit

CPU Traffic Limit

CLI/WEB/SNMP/Telnet/SSH filtering

Spanning-Tree

Rapid Spanning-Tree Protocol

Multi-instance Spanning-Tree Protocol

Network

Management

DHCP Server

DHCP Relay

SNTP Simple Network Time Protocol)

LLDP

Configuration Management

Inband management interface and configuration

Outband management interface and configuration 

Privileged user priority and privileged commands

Network management based on SNMPv1/v2c

Public and private MIB

Public and private Trap

Configuration and management based on WEB

Restore factory default configuration

File system

Upload and download files through FTP or TFTP

System Management

Support FTP, TFTP file upload and download

Support SNTP

Support LLDP neighbor device discovery protocol

Support Ping and Traceroute

Supports configuration management based on WEB pages

Upgrade

Upgrade with the local image file

Upgrade with the remote TFTP server

Online upgrade Uboot

 

Connector Specifications

The switch provides standardized interfaces, thus facilitating rapid and trouble-free integration into the existing network infrastructures.

Network Interfaces

The switch optical interface ports for SFP/SFP+ modules and below table is available SFP/SFP+ module list.

Index

SFP/SFP+ Module Description

1

- Wavelength: 850 nm / Distance: 550 m / Mode: multi-mode

- Connector: LC / Data rate: 1.25Gbit/s / Core type: Dual Core

- Operating Temperature: 0 °C - 70 °C

2

-. Wavelength: 1310nm / Distance: 5km / Mode: single-mode

-. Connector: LC / Data rate: 1.25Gbit/s / Core type: Dual Core

-. Operating Temperature: 0 °C – 70 °C

3

- Wavelength: 1310 nm / Distance: 10 km / Mode: single-mode

- Connector: LC / Data rate: 1.25 Gbit/s / Core type: Dual Core

- Operating Temperature: 0 °C – 70 °C

4

- Wavelength: 1310 nm / Distance: 15 km / Mode: single-mode

- Connector: LC / Data rate: 1.25 Gbit/s / Core type: Dual Core

- Operating Temperature: 0 °C – 70 °C

5

- Wavelength: 1310 nm / Distance: 20 km / Mode: single-mode

- Connector: LC / Data rate: 1.25 Gbit/s / Core type: Dual Core

- Operating Temperature: 0 °C - 70 °C

6

- Wavelength: 1310 nm / Distance: 40 km / Mode: single-mode

- Connector: LC / Data rate: 1.25 Gbit/s / Core type: Dual Core

- Operating Temperature: 0 °C - 70 °C

7

- Wavelength: 850nm / Distance: 300m / Mode: Multimode

- Connector: LC / Data rate: 10.3125 Gbit/s / Core type: Dual Core

- Operating Temperature: 0°C ~ 70 °C

- 10GBASE-SR (10G)

8

- Wavelength: 850nm / Distance: 300m / Mode: Multimode

- Connector: LC / Data rate: 10.3125 Gbit/s / Core type: Dual Core

- Operating Temperature: 0°C ~ 70 °C

- 1000BASE-SX (1G), 10GBASE-SR (10G)

9

 - Wavelength: 1310nm / Distance: 10Km / Mode: Single mode

 - Connector: LC / Data rate: 10.3125 Gbit/s / Core type: Dual Core

 - Operating Temperature: 0°C ~ 70 °C

 - 10GBASE-LR (10G)

10

 - Wavelength: 1550nm / Distance: 40Km / Mode: Single mode

 - Connector: LC / Data rate: 10.3125 Gbit/s / Core type: Dual Core

 - Operating Temperature: 0°C ~ 70 °C

 - 10GBASE-ER (10G)

11

- Wavelength: 1310nm / Distance: 70Km / Mode: Single mode

- Connector: LC / Data rate: 10.3125 Gbit/s / Core type: Dual Core

- Operating Temperature: 0°C ~ 70 °C

- 10GBASE-ZR (10G)

 

Purchase Info

Product Name

Product Description

S5710-12TX

8*10/100/1000M Base-T, 4*1000M Base-X SFP/10GE SFP+, Single Power, Fanless

S5710-28TX

24*10/100/1000M Base-T, 4*1000M Base-X SFP/10GE SFP+, Single Power, 1*FAN

S5710-28TP

24*10/100/1000M Base-T POE, 4*1000M Base-X SFP/10GE SFP+, Single Power, 3*FAN

S5710-54TX

48*10/100/1000M Base-T, 6*1000M Base-X SFP/10GE SFP+, Dual Power,2*FAN

Exhibition Preview

Production Environment
Production Environment
Production Environment
Production Environment
Production Environment
Production Environment
Production Environment
Production Environment

FAQ

Listed below are answers to our most commonly asked questions. Don't see your question?Contact our customer service team. We would be glad to assist you.

What is an optical network terminal (ONT)? How does it differ from a regular modem?

An optical network unit (ONU) is an end device in a fiber optic network that converts optical signals transmitted via fiber optics into electrical signals (for use by routers, computers, and other devices), and vice versa.

What is the architecture of a fiber optic network (PON)?

Fiber optic networks typically use a passive optical network (PON) architecture, which is divided into three layers

What are the functions of the PON port and LAN port on an optical network terminal (ONT)?

PON port (fiber optic interface): Connects to the fiber optic cable entering the home and receives optical signals (usually SC/APC interface, blue square head).

Why does the optical network terminal need to register LOID/SN?

LOID (Logical Identifier) or SN (Serial Number) is the credential used by operators to bind user identities, and is used for OLT authentication of optical modems.

Optical modem dialing vs. router dialing: which is better?

Ordinary users: Optical modem dialing. Game/NAS users: Switch to bridge mode and dial up using a high-performance router.

How to determine whether the fiber optic signal is normal?

Check the optical modem indicator lights Log in to the optical modem management interface: Check the optical power (unit: dBm)

Send enquiry

NOTE: Please leave your email, our professionals will contact you ASAP!