Email: demi@gl-com.com
L3 Managed Ethernet Switch S5710 Series
Category:
Ethernet switch (core layer)
Product Details
Product Overview
The S5710 series switch is a layer 3 Ethernet switch, owns 10 gigabit uplink for enterprise networks and operator customers, which can also meet the needs of cost-effective gigabit access. This device uses a high-performance & low-power network processor, provides gigabit line-speed forwarding performance, supports green Ethernet line sleep capability, which has the lowest power consumption of the same-level equipment in the industry as well. Supports powerful QoS and ACL functions, IP+MAC+ Security features such as port binding support service flow classification and packet priority marking.
The product includes an elastic stacking function, which allows multiple devices to be virtualized into a single logical entity. This not only facilitates the expansion of ports and switching capacity but also enables unified management, upgrades, and maintenance across devices. It can also support static data packet sampling, SFLOW function, multi-port mirroring analysis function, static and flexible QinQ function, strategy-based IPV4/6 unicast routing, and Flexible forwarding strategy.
Device Brief Information
![]() | S5710-12TX |
8* 10/100/1000M Base-T RJ45 port 4* SFP/10G SFP+ port AC input: 100~240V,50/60Hz 11”1U (270*180*44mm) | |
![]() | S5710-28TX |
24* 10/100/1000M Base-T RJ45 port 4* SFP/10G SFP+ port AC input: 100~240V,50/60Hz 19”1U (440*210*44mm) | |
![]() | S5710-28TP |
24* 10/100/1000M Base-T PoE RJ45 port 4* SFP/10G SFP+ port PoE budget: 400W (802.3af/at) AC input: 100~240V,50/60Hz 19”1U (440*260*44mm) | |
![]() | S5710-54TX |
48* 100/1000M Base-T RJ45 port 6* SFP/10G SFP+ port AC input: 100~240V,50/60Hz DC: 40V~60V 19”1U (440*290*44mm) |
Key Features
Carrier-level equipment stability
Based on Linux operating system,support IPv4/IPv6 dual protocol stack platform
Support multiple link redundancy and network redundancy protocols such as STP/RSTP/MSTP/LACP
Stacking Capabilities
Support Stacking of 8 units through a single IP address
Support Unified management
Support Redundancy mechanism
Support High speed interconnect
Perfect safety mechanism
Support link protection functions FlexLink, LACP
Support remote loop detection function
Support remote user authentication based on Tacacs+, Radius, and Local user authentication
Powerful QoS capabilities
Support port speed and flow speed limit function
Support classification based on service flow and Qos flow control function
Support queue scheduling algorithms such as SP/WRR/SP+WRR
Support port-based and service flow-based mirroring functions
Rich management protocols
Support easy-to-use network management function
Support CLI based on RS232 serial port, Telnet and SSHv2
Support WEB-based configure operation management, support SNMP V1/V2/V3
Support remote upgrade or equipment through FTP and TFTP
Hardware Specifications
Attributes | S5710-12TX | S5710-28TX | S5710-28TP | S5710-54TX |
Port | 8*10/100/1000M/ Ethernet port 4 *10G SFP+ | 24*10/100/1000M/ Ethernet port 4 *10G SFP+ | 24*10/100/1000M/ Ethernet port/POE 4 *10G SFP+ | 48*10/100/1000M/ Ethernet port 6 *10G SFP+ |
Chipset | RTL9301 | RTL9311 | ||
Switching Capacity | 96Gbps | 128Gbps | 216Gbps | |
Forwarding Rate | 71.43Mpps | 95.24Mpps | 160.71Mpps | |
MAC | 16K | 32K | ||
Multicast | 1K | 4K | ||
Packet Buffer | 12Mbit | 16Mbit | ||
ARP Table | 2K | 8K | ||
Routing Table | 512 | 12K | ||
PoE Budget | N/A | N/A | 415W(af/at) | N/A |
Memory and Storage | Memory: 512MB, Storage:32MB | |||
Power Supply | AC: 100~240V 50/60Hz; | |||
Power Consumption | Idle ≤10W Full load ≤20W | Idle ≤13W Full load ≤30W | Idle ≤15W Full load ≤450W | Idle ≤25W Full load ≤53W |
Weight | 1.6kg | 2.6kg | 4.2Kg | 4.2kg |
Dimensions (WxDxH) | 270X180X44mm | 440X210X44mm | 440X260X44mm | 440×290×44mm |
Temperature | Working Temperature:-10℃~50℃; Storage Temperature:-40℃~70℃ | |||
Humidity | Relative Humidity: 5%~95%, non-condensing | |||
Panel view
![]() | |
LED indicator
Color | Function | Description | ||
PWR | Green | Power status | ON | The AC power module is normal. |
OFF | The AC power module faulty or unavailable. | |||
SYS | Green | System running status | Green OFF | The device is not running or power off. |
Green Flash | The device is running normally. | |||
ALARM | RED | Hardware state | ON | The fan or power module is abnormal |
OFF | Components working properly. | |||
POE MAX | Green | Power Threshold | ON | Maximum power supplied by POE. |
OFF | The POE power supply indicates the normal range. | |||
GE/SFP Port | Green | Port status | ON/Flash | The link is properly connected (link up) and in action Works in Gigabit mode. |
| OFF | The link is interrupted (link down). | ||
Orange | ON/Flash | The link is properly connected (link up) and in action Works in 10/100Mbps mode. | ||
POE | Green | PD status | ON | The POE port is connected to the PD device and starts to supply power. |
OFF | No PD is connected to the device. | |||
Plug-In Units
Power Supply Unit (PSU)
The S5710 series devices are equipped with a built-in AC power module and provide an AC power port on the back of the device.
The below shows the electrical characteristics of the switch:
Characteristic | S5710 Series |
Nominal AC power supply | AC: 100~240V; 47/63Hz |
FAN Unit
The fans of the device run according to the power of the device environment. A built-in fan group is installed on the side of the chassis. The fan group can be as follows:
Characteristic | FAN |
S5710-12TX | 0*FAN |
S5710-28TX | 1*FAN |
S5710-28TP | 3*FAN |
S5710-54TX | 2*FAN |
Software Specifications
Attributes | S5710 Series |
VLAN | Support 4K VLAN Support VLAN based on port, MAC and protocol Support dual Tag VLAN, Access/Trunk/Hybrid |
Ethernet | Ethernet interface operating modes Ethernet interface operating rates Jumbo Frame Port enable/disable Port based storm-control Unknow-unicast/unknow-multicast/broadcast storm-control Port-isolate |
Stackable | Support Stacking of 8 units through a single IP address Support Unified management Support Redundancy mechanism Support High speed interconnect |
MAC | Support static MAC address setting Support black hole MAC address filtering Support port MAC address limit Automatic learning and aging of MAC addresses |
ARP | Static and dynamic ARP entries Aging of ARP entries ARP-Proxy |
Port Control | Support two-way bandwidth control Support port storm suppression Support 9K Jumbo ultra-long frame forwarding |
Port Aggregation | Support static link aggregation Support dynamic LACP Each aggregation group supports a maximum of 8 ports LAG load balance(SIP/DIP/SMAC/DMAC) |
Mirroring | Supports multi-port mirroring analysis Service flow-based image analysis |
ACL | Support standard and extended ACL Support ACL policy based on time period Provide MAC, IP, L4 port and port level security control functions |
QoS | Traffic classification based on COS/DSCP (simple classification) Traffic classification based on ACL (complex classification) Traffic classification based on inner header of the tunnel packets Queue scheduling Remark the priority fields (COS/DSCP) of the packet based on ACL Traffic policing based on direction(in/out) of Port Traffic policing based on direction(in/out) of VLAN Traffic policing based on direction(in/out) of flow Traffic policing based on direction(in/out) of aggregated flow SP(Strict Priority)scheduling WRR(Weighted Round Robin)scheduling SP + WRR mixed scheduling |
Safety | Support Radius & TACACS+ authentication Support port isolation Support broadcast message rate suppression Support IP Source Guard Support ARP flood suppression and ARP spoofing protection |
Layer 3 | Support ARP learning and aging Support IPv4static route Support dynamic route RIP/OSPF Support IPv4/IPv6 dual-stack platform Support CLI、Telnet、WEB、SNMP V1/V2/V3、SSHv2 mode |
Terminal Services | Configurations through CLI Console Terminal service |
Maintenance | Per-module Debug features CPU usage display and alarm Memory usage display and alarm User operation logs Management of logs, alarms, and debugging information Manual reboot Reboot Information logging Ping IPv6 Ping Traceroute To CPU/From CPU packets statistics Time configuration Timezone |
System Security | SSHv1/v2 RADIUS TACACS+ MAC/IP ACL Port/VLAN/L4-Port ACL IP Source Guard Limitation on MAC address learning on interface Rate limit CPU Traffic Limit CLI/WEB/SNMP/Telnet/SSH filtering |
Spanning-Tree | Rapid Spanning-Tree Protocol Multi-instance Spanning-Tree Protocol |
Network Management | DHCP Server DHCP Relay SNTP Simple Network Time Protocol) LLDP |
Configuration Management | Inband management interface and configuration Outband management interface and configuration Privileged user priority and privileged commands Network management based on SNMPv1/v2c Public and private MIB Public and private Trap Configuration and management based on WEB Restore factory default configuration |
File system | Upload and download files through FTP or TFTP |
System Management | Support FTP, TFTP file upload and download Support SNTP Support LLDP neighbor device discovery protocol Support Ping and Traceroute Supports configuration management based on WEB pages |
Upgrade | Upgrade with the local image file Upgrade with the remote TFTP server Online upgrade Uboot |
Connector Specifications
The switch provides standardized interfaces, thus facilitating rapid and trouble-free integration into the existing network infrastructures.
Network Interfaces
The switch optical interface ports for SFP/SFP+ modules and below table is available SFP/SFP+ module list.
Index | SFP/SFP+ Module Description |
1 | - Wavelength: 850 nm / Distance: 550 m / Mode: multi-mode - Connector: LC / Data rate: 1.25Gbit/s / Core type: Dual Core - Operating Temperature: 0 °C - 70 °C |
2 | -. Wavelength: 1310nm / Distance: 5km / Mode: single-mode -. Connector: LC / Data rate: 1.25Gbit/s / Core type: Dual Core -. Operating Temperature: 0 °C – 70 °C |
3 | - Wavelength: 1310 nm / Distance: 10 km / Mode: single-mode - Connector: LC / Data rate: 1.25 Gbit/s / Core type: Dual Core - Operating Temperature: 0 °C – 70 °C |
4 | - Wavelength: 1310 nm / Distance: 15 km / Mode: single-mode - Connector: LC / Data rate: 1.25 Gbit/s / Core type: Dual Core - Operating Temperature: 0 °C – 70 °C |
5 | - Wavelength: 1310 nm / Distance: 20 km / Mode: single-mode - Connector: LC / Data rate: 1.25 Gbit/s / Core type: Dual Core - Operating Temperature: 0 °C - 70 °C |
6 | - Wavelength: 1310 nm / Distance: 40 km / Mode: single-mode - Connector: LC / Data rate: 1.25 Gbit/s / Core type: Dual Core - Operating Temperature: 0 °C - 70 °C |
7 | - Wavelength: 850nm / Distance: 300m / Mode: Multimode - Connector: LC / Data rate: 10.3125 Gbit/s / Core type: Dual Core - Operating Temperature: 0°C ~ 70 °C - 10GBASE-SR (10G) |
8 | - Wavelength: 850nm / Distance: 300m / Mode: Multimode - Connector: LC / Data rate: 10.3125 Gbit/s / Core type: Dual Core - Operating Temperature: 0°C ~ 70 °C - 1000BASE-SX (1G), 10GBASE-SR (10G) |
9 | - Wavelength: 1310nm / Distance: 10Km / Mode: Single mode - Connector: LC / Data rate: 10.3125 Gbit/s / Core type: Dual Core - Operating Temperature: 0°C ~ 70 °C - 10GBASE-LR (10G) |
10 | - Wavelength: 1550nm / Distance: 40Km / Mode: Single mode - Connector: LC / Data rate: 10.3125 Gbit/s / Core type: Dual Core - Operating Temperature: 0°C ~ 70 °C - 10GBASE-ER (10G) |
11 | - Wavelength: 1310nm / Distance: 70Km / Mode: Single mode - Connector: LC / Data rate: 10.3125 Gbit/s / Core type: Dual Core - Operating Temperature: 0°C ~ 70 °C - 10GBASE-ZR (10G) |
Purchase Info
Product Name | Product Description |
S5710-12TX | 8*10/100/1000M Base-T, 4*1000M Base-X SFP/10GE SFP+, Single Power, Fanless |
S5710-28TX | 24*10/100/1000M Base-T, 4*1000M Base-X SFP/10GE SFP+, Single Power, 1*FAN |
S5710-28TP | 24*10/100/1000M Base-T POE, 4*1000M Base-X SFP/10GE SFP+, Single Power, 3*FAN |
S5710-54TX | 48*10/100/1000M Base-T, 6*1000M Base-X SFP/10GE SFP+, Dual Power,2*FAN |
Exhibition Preview
FAQ
Listed below are answers to our most commonly asked questions. Don't see your question?Contact our customer service team. We would be glad to assist you.
What is an optical network terminal (ONT)? How does it differ from a regular modem?
What is the architecture of a fiber optic network (PON)?
What are the functions of the PON port and LAN port on an optical network terminal (ONT)?
Why does the optical network terminal need to register LOID/SN?
Optical modem dialing vs. router dialing: which is better?
How to determine whether the fiber optic signal is normal?
Recommend
Send enquiry
NOTE: Please leave your email, our professionals will contact you ASAP!